Installatiekabel

MTW TC-ER Power Cable

DESCRIPTION
Print Friendly, PDF & Email

Increased oil-resistant Control and Power supply cable, conform NFPA 79 2007 wiring norms and NEC 336.10(7). Manufactured according UL 1277 (Tray cable – Exposed run – Oil resistant) and UL 1063 (MTW).

These cables are suitable for control equipment on machine tools subjected to medium mechanical stress. Suitable for fixed or flexible installation, where free movement is required without tensile stress and without forced guidance systems, in dry, damp and/or wet interiors (including water-oil mixtures).

Machine tools compliant with UL MTW (Machine Tool Wiring) TC-ER (Tray Cable Exposed Run) approval for open wiring between cable tray and industrial machines/plants acc. to NEC 336.10(7) Class 1, Div. 2 in accordance with NEC "National Electrical Code" Art. 336, 392, 501.

Oil-resistant according to UL OIL RES I and Water-resistant, UL Wet Approval 75 °C.

MTW TC-ER Tray Cable Product Specification
FlammabilityAccording category FT4/IEEE of Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables, UL 1685 standard.
ConstructionAccording to UL 1277 and UL 1063 ( Oil-resistant according to UL OIL RES I and Water-resistant, UL Wet Approval 75 °C )
NormsAccording to UL 2277 Flexible Motor Supply Lead Cable (ZJFH) and Wind Turbine Tray Cable (ZGZN)
According to CSA 239-09 Standard for Control and Instrumentation Cables
American and Canadian UL recognized according UL AWM styles 10012, 2587 and CSA AWM I/II A/B
CSA FT4/IEEE
The cable is conform to Low Voltage Directive (LVD) 2014/35/EU CE
Other CompliancesTC-ER approval acc. NEC 336.10(7), Class 1, Div. 2 in accordance with NEC "National Electrical Code" Art. 336, 392, 501
MTW TC-ER Tray Cable Product Specification
ConductorTFF for sizes 1 and 1.5mm², THHW for >1.5mm²
Flexible bare copper conductors according to CEI 20-29 Class 5, DIN-VDE 0295 K5 and UL 83 standard
InsulationSpecial PVC Insulation compound type QMTT2
Black numbered cores, with green/yellow
JacketOuter sheath in special PVC according to UL 1277 and UL 1063
Nominal Voltage600V
Spark Test Voltage6000V
Fixed Installation working temp-40°C to + 90°C
Minimum installation temp -25°C
Conductor Sizes
Available on request, metric or AWG copper construction possible.